Gas Point H2S, CO, NH3, HCN, NO2, SO2, O2, Cl2 Combustibles (Catalytic 0-100% LEL) or Combustibles (IR 0-100% LEL) Gas Transmitter with Internal Alarm Relays www.gasmonitors.com e-mail: info@gasmonitors.com Ordering Information GP-WD Gas Transmitter with Combustible Catalytic Sensor GP-IR-WD Gas Transmitter with Combustible Infrared Sensor GP-HD Gas Transmitter with H2S Sensor GP-MD Gas Transmitter with CO Sensor GP-AD Gas Transmitter with NH3 Sensor GP-ZD Gas Transmitter with HCN Sensor GP-DD Gas Transmitter with NO2 Sensor GP-SD Gas Transmitter with SO2 Sensor GP-XD Gas Transmitter with O2 Sensor GP-CD Gas Transmitter with Cl2 Sensor Accessories and Spares GP-POWER1 120-240 VAC Power Supply GP-MBUS4 2-wire/4-wire MODBUS Communication Expansion Module GP-SEP Sensor Separation Kit GP-1 Gas Transmitter GP-SSPB Stainless Steel Process Baffl e GP-SSCAL4 Stainless Steel GasPoint Splash Guard GP-DUC-K1 Duct Mount Adaptor Replacement Sensor Assemblies SS-RH02.....H2S SS-RM02.....CO SS-RA02.....NH3 SS-RZ02.....HCN SS-RD02.....NO2 SS-RC02.....Cl2 SS-RS02.....SO2 SS-RX02.....O2 SS-RW02....Combustible Catalytic Sensor Assembly IR-RW03.....Combustible IR Sensor Assembly FEATURES: Fixed Gas Monitoring Systems The GasPoint transmitter provides a 4-20 mA output signal that can be connected to any control system (DCS, PLC, etc.). With advanced sensor technology and microcontroller based operation, the GasPoint provides continuous monitoring of hazardous gases. The GasPoint transmitter can accept any GasPoint sensor type: electrochemical, catalytic or IR (infrared). All plug-in sensor assemblies are fi eld-interchangeable. Full function sensor integrity test (auto) continuously advises gas sensing ability and life ended Non-intrusive, one-person calibration with auto zero and auto span Equipped with three 5-amp relay contacts—two gas alarm relays (low/high) and fault alarm. Field-selectable normally energized/ de-energized and latching/non-latching alarm relay functions. Two backlit alphanumeric LCDs advise all environmental and gas hazard conditions as well as instrument and sensor status Remote toxic/oxygen sensors can be installed over 3,900 ft./ 1,100 m away; combustible sensors over 1,550 ft./475 m. Kit can be installed at any time. Alarm setpoints displayed on demand—simply press the external button Field programmable alarm levels Backlight (auto) in low light conditions and alarm Extensive fault diagnostics 2-way digital communication using MODBUS module n One Transmitter with interchangeable electrochemical, infrared and catalytic plug-in sensorsGasPoint LEL, H2S, CO, NH3, HCN, NO2, SO2, Cl2 or O2 4-20 mA Gas Transmitter Display advises: Gas type monitored Continuous (%LEL, %v/v or ppm) readout of gas concentration Alarm level and type encountered - LOW/HIGH or FAULT When sensor has failed its automatic daily self-test “Sensor Replacement” and “Sensor Expired” indications When to apply gas during calibration Special Features Change gases monitored in the fi eld at any time. The GasPoint Transmitter will recognize the sensor installed and test and reset itself to that sensor type. No junction box connection required. Daily sensor integrity test (auto) monitors sensor operation, length of time sensor has been in service and advises when sensor requires replacement. GasPoint allows you to set or change calibration time and gas alarm setpoints in the fi eld. Select or modify the measuring range using a simple dipswitch. The optional plug-in MODBUS expansion module provides an addressable communications interface (1-247). RATINGS AND CERTIFICATIONS: Locally distributed by: n Class I, Div. 1, Groups B, C, D (LEL and IR models) Class I, Div. 1, Groups B, C, D; Class II, Div. 1, Groups E, F, G (toxic models only) Explosion-proof: ANSI/ISA: UL 1203; CSA: C22.2 No 30 Combustible Performance Standards: ANSI/ISA: ISA-S12.13; CSA: C22.2 No 152 SPECIFICATIONS MONITOR: 3-wire, 4-20 mA gas transmitter with advanced microcontroller-based circuitry Power Input: 12 to 32 volts DC Output Current: Normal Operation: Isolated linear 4-20 mA output Calibration Mode: Steady 3 mA (auto reset to normal operation) Fault Mode: 2 mA signal (and less) Power Consumption: Toxic Versions: 40 mA at 24 VDC Combustible Version: 100 mA at 24 VDC Relays: 50 mA per relay at 24 VDC SENSORS: Plug-in, smart sensors Detection Type: Combustible gases: catalytic or IR; Toxic gases and Oxygen: electrochemical Self-Test:: Automatic daily self-test of sensor integrity and sensor life Relative Humidity: 5 to 95% RH non-condensing Drift: Zero: <5% per year; Span: <10% per year *Factory default setting **Note: Cl2 not rated for Class I, Div. 1 CALIBRATION: Non-intrusive, via pushbutton Auto zero and auto span DISPLAYS: Two backlit liquid crystal displays LCD 1 3-digit continuous readout of the gas present (ppm, % LEL or %v/v) LCD 2 Alphanumeric diagnostic status display Alarm Setpoints: Two setpoints: user-selectable RELAY CONTACTS: Three SPDT relays; 5 amps at 250 VAC LOW/HIGH: Field selectable for normally energized/de-energized and latching/ non-latching FAULT: Normally energized and non-latching TRANSMISSION RANGES: Relay contacts not considered. (For ranges with relays see manual.) 1 Large, backlit LCD readout of gas concentration 2 Alphanumeric LCD showing transmitter STATUS and diagnostics 3 Non-intrusive calibration via simple pushbutton 4 Interchangeable sensor types: LEL (catalytic or IR), toxic gas or oxygen with common transmitter assembly 5 Three relays: two gas alarm relays, one fault relay DUE TO ONGOING RESEARCH AND PRODUCT IMPROVEMENT, SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Gas Monitoring Specifi cations Detectable Accuracy LCD Increment Temperature Range Units Programmed Measuring Ranges Combustibles - Catalytic 1% 1 -40 to +90°C / -40 to +194°F %LEL 0-100* Combustibles - Infrared 1% 1 -40 to +70°C / -40 to +150°F %LEL 0-100* H2S 0.25 ppm 1 -40 to +50°C / -40 to +122°F ppm 0-20, 0-50, 0-100*, 0-500 CO 1 ppm 1 -20 to +50°C / -4 to +122°F ppm 0-50, 0-100, 0-500*, 0-1,000 NH3 1 ppm 1 -10 to +50°C / +14 to +122°F ppm 0-50*, 0-100, 0-500, 0-1,000 HCN 0.1 ppm 0.1 -20 to +50°C / -4 to +122°F ppm 0-20.0*, 0-50.0, 0-100 NO2 0.1 ppm 0.1 -20 to +50°C / -4 to +122°F ppm 0-50.0*, 0-10.0, 0-20.0, 0-99.9 SO2 1 ppm 1 -20 to +50°C / -4 to +122°F ppm 0-100*, 0-50, 0-20, 0-10 O2 0.1% 0.1 -20 to +50°C / -4 to +122°F %v/v 0-30.0%* Cl2** 0.1 ppm 0.1 -20 to +50°C / -4 to +122°F ppm 0-5.0*, 0-10.0, 0-100.0 Conductor Size Toxic / Oxygen Sensors Combustible Sensors 22 AWG 0.64 mm 6,712 ft. 2,045 m 3,356 ft 1,022 m 20 AWG 0.75 mm 10,953 ft. 3,253 m 5,336 ft. 1,626 m 18 AWG 1.0 mm 16,953 ft. 5,167 m 8,476 ft. 2,583 m CONTROLS: Calibration: Non-intrusive via external pushbuttonM Alarm Setpoints: Simple up/down pushbuttons with LCD readout of setpoints PHYSICAL: Size: 6.8 x 7 x 4.3 inches / 17 x 17.8 x 10.8 cm (approx.) Weight: 4.85 lb. / 2.2 kg (approx.) Transmitter: Nema 4, explosion-proof, anodized aluminum enclosure with mounting fl anges Sensor: Stainless steel enclosure WARRANTY: Instrument: 2 years non-prorated; Sensor: 2 years full replacement warranty 1 4 3 2 For further information: 1-888-749-8878 USA 1-800-663-4164 Canada +44 (0)1295 700 300 Europe +33 (0) 442 98 17 70 France +971-4-8871766 Middle East +61-3-9464-2770 Australia +86 10 6786 7305 China +65 6748 4915 South East Asia +1-403-248-9226 Other Countries Corporate Headquarters 2840 - 2 Avenue S.E. Calgary, AB, Canada T2A 7X9 Phone: 1-403-248-9226 Fax: 1-403-273-3708 e-mail: info@gasmonitors.com www.gasmonitors.com BW1021-01-01-00-8.25x11-20070612-5124-7 © 2007 Honeywell International Ltd. All Rights Reserved.